Defaults

Default Alarm Philosophy

The web portal comes with preconfigured alarms. Our experience shows that over-sensitive alarms can lead to users ignoring them, undermining their value. Therefore, our default settings prioritize generating alarms late rather than too early.

You are encouraged to adjust these settings based on your knowledge of specific installations to create stricter and more timely rules where appropriate.

This page gives an overview of the alarms which are configured by default.

NameTypeSupervised signalsSupervised node typesRules
No production dataNo data• Active production power• Installation
• Smart grid controller site
• Inverter
• Hybrid inverter
• String
• All: lookback period from 9 hours ago to 0 hours ago, time window from 09:00 to 18:00
No energy storage dataNo data• Active storage power• Installation
• Smart grid controller site
• Battery
• Hybrid inverter
• All: lookback period from 24 hours ago to 0 hours ago
No charger dataNo data• Active charger power• Installation
• Smart grid controller site
• EV charger
• EV charger connector
• All: lookback period from 24 hours ago to 0 hours ago
No grid dataNo data• Active grid power• Installation
• Smart grid controller site
• Wind Farm
• All: lookback period from 24 hours ago to 0 hours ago
No dataNo data• Active power (generic)• Power meter
• Switch board
• Hybrid inverter
• All: lookback period from 24 hours ago to 0 hours ago
Production is zeroLow delta• Produced energy• Installation
• Smart grid controller site
• Inverter
• Hybrid inverter
• String
• All: lookback period from 9 hours ago to 0 hours ago, time window from 09:00 to 18:00
Storage energy is zeroLow delta• Storage charged energy
• Storage discharged energy
• Installation
• Smart grid controller site
• Battery
• Hybrid inverter
• All: lookback period from 24 hours ago to 0 hours ago
Charger energy is zeroLow delta• Charger charged energy
• Charger discharged energy
• Installation
• Smart grid controller site
• EV charger
• EV charger connector
• All: lookback period from 7 days ago to 0 days ago*
Grid energy is zeroLow delta• Grid imported energy
• Grid exported energy
• Installation
• Smart grid controller site
• Wind Farm
• All: lookback period from 24 hours ago to 0 hours ago
Energy measurements are zeroLow delta• Imported energy (generic)
• Exported energy (generic)
• Power meter
• Switchboard
• Hybrid inverter
• All: lookback period from 24 hours ago to 0 hours ago
Low PRLow performance ratioN/A• Installation
• Smart grid controller site
• Inverter
• Hybrid inverter
• String
• All: lookback period from 3 days ago to 1 days ago, threshold of 50%**
Low uptimeLow uptimeN/A• Installation
• Smart grid controller site
• Inverter
• Hybrid inverter
• String
• All: lookback period from 3 days ago to 1 days ago, threshold of 80%**
Charger Energy Lookback (*)

It is not uncommon for an EV charger to remain unused for several days. Consequently, the default lookback period for the "Charger energy is zero" alarm is set to 7 days to avoid frequent nuisance alarms.

PR and Uptime Considerations (**)
  • Meteo Data Dependency: Both Performance Ratio (PR) and Uptime calculations require meteorological data (like irradiation). Depending on the data source and location, this data might have a delay of up to a day.
  • Fluctuations: PR values can fluctuate based on the accuracy of meteo data and specific daily weather conditions (e.g., rapidly changing cloud cover).

The default lookback period (3 days ago to 1 day ago) and thresholds (50% for PR, 80% for Uptime) to account for these potential delays and fluctuations.